ClinConnect ClinConnect Logo
Search / Trial NCT06501872

Safety and Effectiveness of Physician-Modified Fenestrated and Branched Aortic Endografting for the Treatment of Thoracoabdominal and Pararenal Aortic Aneurysms

Launched by BJOERN D. SUCKOW · Jul 8, 2024

Trial Information

Current as of June 26, 2025

Recruiting

Keywords

Aortic Aneurysm

ClinConnect Summary

This clinical trial is looking at a new treatment option for people with thoracoabdominal aortic aneurysms, which are bulges in the aorta that can be dangerous if they grow too large. The study is testing a specially modified aortic stent graft to see if it is safe and effective compared to traditional open surgery. The goal is to determine if this new approach can help patients who are at high risk for surgery, potentially offering a less invasive solution.

To participate in this trial, individuals must be at least 50 years old and have a specific type of aortic aneurysm that is large enough to require treatment. Participants will undergo a five-year follow-up to monitor their health and the effectiveness of the treatment. It’s essential for potential participants to understand that they will need to commit to this study schedule and that certain health conditions may prevent them from joining. Overall, this trial aims to provide valuable insights into a promising new method for treating aortic aneurysms safely.

Gender

ALL

Eligibility criteria

  • Main Arm Inclusion Criteria:
  • Must be a man or woman 50 years of age or older by the date of informed consent
  • Must have a thoracoabdominal aortic aneurysm of any Crawford classification (extent I-V) that extends no more proximal than the left subclavian artery.
  • Must have an aneurysm size that meets standard indications for surgical repair (6.0 cm in maximum diameter in the descending thoracic aorta, or 5.5 cm in maximum diameter in the abdominal aorta)
  • Must be considered, in the judgement of the Investigator, to be a high- risk candidate for open surgical repair
  • Must commit to comply with the five-year study assessment schedule of events
  • Must have a non-aneurysm-related life expectancy, in the judgement of the Investigator, of greater than 2 years
  • Expanded Selection Inclusion Criteria:
  • Must be a man or woman 50 years of age or older by the date of informed consent
  • Must have a thoracic, thoracoabdominal, or abdominal aortic aneurysm that necessitates coverage of one or more visceral vessels (celiac, superior mesenteric, or renals) for establishment of proximal and/or distal seal. The aneurysm must not extend proximal to the left subclavian artery, or, in the setting of more proximal disease, that disease must have been previously treated.
  • Must have an aneurysm size that meets standard size indications for surgical repair (6.0 cm in maximum diameter in the descending thoracic aorta, or 5.5 cm in maximum diameter in the abdominal aorta); or, in the judgment of the Investigator, has aneurysm characteristics that portend a high risk of near-term rupture
  • * In the setting of an aortic dissection the following criteria must exist:
  • Access into the true lumen from the groin and at least one supra-aortic trunk vessel
  • A sealing zone in the target aorta (or surgical graft) that is proximal to the primary dissection, such that a stent graft would be anticipated to seal off the dissection lumen
  • A sealing zone in the target supra-aortic trunk vessels that is distal to the dissection, anticipated to seal off the dissection lumen, or surgically created
  • A true lumen size large enough to deploy the device and still gain access into the target branches
  • Must be considered, in the judgement of the Investigator, to be a high-risk candidate for open surgical repair
  • Patient must be able to provide informed consent
  • Must commit to comply with the five-year study assessment schedule of events
  • Must have a non-aneurysm-related life expectancy, in the judgement of the Investigator, of greater than 2 years
  • Main Arm Exclusion Criteria:
  • Aneurysm due to acute or chronic dissection, intramural hematoma, penetrating aortic ulceration, pseudoaneurysm, mycotic aneurysm, or traumatic transection
  • Ruptured or acutely symptomatic aortic aneurysm
  • Known connective tissue disorder
  • * Imaging demonstrating any of the following:
  • Lack of 20 mm non-aneurysmal proximal seal zone (zone 3, or zone 2 with a carotid-subclavian bypass or transposition)
  • Lack of 15 mm non-aneurysmal distal seal zone(s) (aortic, common iliac, or external iliac)
  • Branch vessel target (renal, superior mesenteric, or celiac) \< 5 mm or \> 10 mm in average diameter
  • Untreated left subclavian artery stenosis or occlusion
  • Untreated unilateral or bilateral hypogastric artery occlusion
  • Signs that the inferior mesenteric artery is indispensable
  • Have branching, duplication, aneurysm, or untreatable stenosis of the celiac, superior mesenteric artery, or renal arteries that would preclude implantation of the investigational devices
  • Known allergies to stainless steel, PTFE, polyester, polypropylene, nitinol, or gold
  • History of anaphylaxis to contrast, with inability to prophylax appropriately.
  • Have uncorrectable coagulopathy
  • Have unstable angina
  • Have a body habitus that would inhibit X-ray visualization of the aorta
  • Have a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤30 days of the endovascular repair
  • Known to be participating in any other clinical study which may affect performance of this - Ability to bear children
  • Contraindication to oral antiplatelet therapy
  • Prisoners or those on alternative sentencing
  • Known systemic infection with potential for endovascular graft infection
  • Anticipated need for MRI scanning within 3 months of insertion of investigational product
  • Candidate for repair under the Instructions for Use of a commercially available, FDA-approved endovascular graft
  • Can enroll in a manufacturer-sponsored clinical study at our institution or is willing and eligible to participate in a study with a manufacturer-made device at another institution.
  • Expanded Selection Exclusion Criteria:
  • Known or suspected mycotic aneurysm
  • Ruptured aneurysm with hemodynamic instability
  • Known connective tissue disorder
  • * Imaging demonstrating any of the following:
  • Lack of 20 mm non-aneurysmal proximal seal zone (in either native aorta, elephant trunk graft, or aortic arch endograft)
  • Lack of 15 mm non-aneurysmal distal seal zone(s) (in either native aortoiliac vessels, prosthetic aortoiliac grafts, or aortoiliac endografts)
  • Branch vessel target (renal, superior mesenteric, or celiac) \> 10 mm in average diameter
  • Known allergies to stainless steel, PTFE, polyester, polypropylene, nitinol, or gold
  • History of anaphylaxis to contrast, with inability to prophylax appropriately.
  • Have uncorrectable coagulopathy
  • Have a body habitus that would inhibit X-ray visualization of the aorta
  • Have a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤ 30 days of the endovascular repair
  • Known to be participating in any other clinical study which may affect performance of this device
  • Ability to bear children
  • Contraindication to oral antiplatelet therapy
  • Prisoners or those on alternative sentencing
  • Known systemic infection with potential for endovascular graft infection
  • Anticipated need for MRI scanning within 3 months of insertion of investigational product
  • Candidate for repair under the Instructions for Use of a commercially available, FDA- approved endovascular graft
  • Can enroll in a manufacturer-sponsored clinical study at our institution or is willing and eligible to participate in a study with a manufacturer-made device at another institution
  • Other conditions or comorbidities that, in the opinion of the Investigator, would exclude the patient

About Bjoern D. Suckow

Bjoern D. Suckow is a dedicated clinical trial sponsor with a strong commitment to advancing medical research and improving patient outcomes. With extensive experience in clinical development, Mr. Suckow focuses on innovative therapies and evidence-based practices across various therapeutic areas. His leadership emphasizes rigorous study design, regulatory compliance, and ethical standards, ensuring the integrity and reliability of clinical trials. By fostering collaborative partnerships with healthcare professionals and research institutions, he aims to accelerate the translation of scientific discoveries into effective treatments for patients in need.

Locations

Lebanon, New Hampshire, United States

Patients applied

0 patients applied

Trial Officials

Bjoern D Suckow, MD

Principal Investigator

Dartmouth-Hitchcock Medical Center

Timeline

First submit

Trial launched

Trial updated

Estimated completion

Not reported